DS-5554A |
DS-5552A |
DS-5534A |
DS-5532A |
DS-5524A |
DS-5522A |
DS-5514A |
DS-5512A |
Frequency bandwidth(-3dB) |
500MHz |
350MHz |
200MHz |
100MHz |
Rise time(Typical)) |
750ps |
1ns |
1.75ns |
3.5ns |
Input Channel |
4 |
2 |
4 |
2 |
4 |
2 |
4 |
2 |
Maximum Sampling Speed |
1GS/s(all CHs)/ 2GS/s(Channel combined) |
1GS/s |
Equivalent Sampling Rate |
100GS/s |
Peak detect resolution |
1ns |
Averaging |
2 to 256 times |
Maximum Memory Length |
1Mpts/ch(for all CHs) |
Vertical Resolution |
8-bit |
Input voltage range |
2mV/div - 10V/div(1MΩ), 2mV/div - 2V/div(50MΩ) |
2mV/div - 10V/div(1MΩ) |
Offset voltage |
2mV/div - 50mV/div : ±1V
50.2mV/div - 500mV/div : ±10V
502mV/div - 10V/div : ±100V |
DC gain accuracy |
±1.5% + (0.5% of fullscale) |
Maximum Input Voltage |
±400Vpeak CAT I (1MΩ), 5Vrms (50Ω) |
±400Vpeak CAT I (1MΩ) |
Band-limiting filter |
Analog form : 100MHz,20MHz,2MHz,200kHz |
Analog form : 20MHz,2MHz,200kHz |
Digital form : Either of LPF/HPF/OFF is selected with each channel.
4 independent channels |
Input coupling |
GND, DC 1MΩ, AC 1MΩ,DC50Ω |
GND, DC 1MΩ, AC 1MΩ |
Input Impedance |
1MΩ±1% //16pF、 50Ω±1% |
1MΩ±1% //20pF |
Probe sense |
Automatic: 1:1、10:1、100:1、1000:1
Manual: 1:1、5:1、10:1、20:1、50:1、100:1、200:1、500:1、1000:1、2000:1 |
Timebase |
500ps/div ~ 50s/div |
1ns/div ~ 50s/div |
2ns/div ~ 50s/div |
5ns/div ~ 50s/div |
Standard probe |
SS-101R (multi-channel) |
SS-0130R (multi-channel) |
Roll mode |
50ms/div ~ 50s/div (100kS/s max) |
Timebase (Clock) accuracy |
±10 ppm |
Trigger function |
Trigger type |
Edge, Edge ALT, Edge OR, Pulse Count, Pulse Width, Period,Dropout, TV, OR, NOR, AND, NAND |
TV mode /
Line number /
Field sequence |
NTSC, PAL, Custom / upto 3,000 / 1, 2, 4 & 8 fields |
Pulse Count Trigger |
1 to 9999 events |
Pulse Width Trigger |
15ns to 50s |
Period Trigger |
40ns to 50s |
Dropout Trigger |
50ns to 50s |
Pattern Trigger |
OR、NOR、AND、NAND |
Trigger source /
Status /
threshhold level setting |
All channels / High, Low、 Don't Care / All channels set independently |
Trigger Source |
Input CHs, Line, EXT(+/-0.5V), EXT10(+/-5.0V) |
Trigger Slope /Coupling |
+,- / AC, DC, HF Rej, LF Rej, Noise Rej |
Display function |
Display size/ resolution |
7.5inch color TFT-LCD with Touch screen / VGA(640*480pixels) |
Display mode |
YT、XY、XY (Triggered) |
Vector Display Method |
Interpolation on sample points or Dots |
Analog persistence mode |
Monochrome grayscale or Color Spectrum |
Persistence time setting |
100ms, 200ms, 500ms, 1s, 2s, 5s, 10s & Infinite |
Reference waveform memory |
5 waveforms |
Panel setting memory |
5settings for Internal memory or USB memory |
Parameter measurement, Cursor, Zoom, Calculation, Replay |
rameter measurement |
Maximum, Minimum, Peak-Peak, RMS, Cycle RMS, Mean, Cycle Mean, Top, Base, Top-Base, +Overshoot, -Overshoot, Tr 20-80%, Tf 80- 20%, Tr 10-90%, Tf 90-10%, Freq., Period, +Pulse Count, -Pulse Count, +Pulse Width, -Pulse Width, Duty Cycle, Integral, Skew (+, -), Skew at level |
Concurrent number of measurements /
statistics display |
Four parameter maximum /Max (Maximum), Min (Minimum) ,Num (Number of the total waveforms) |
Logging item, destination |
Time and parameter measurement results (conditions A, B, C, D),
Pass/Fail judgment results When recording: Pop-up window,
internal memory (up to 86400 entries), After recording: USB memory |
Pass/Fail |
Judgment mode: Select between Parameter judgment and Mask judgment,
Judgment result: Save waveform (USB memory)/ Beep/ Pulse output (when equipped with DS-578 option)/ Logging,
Page search function: Select any of Fail or Pass, you can search forward or backward |
Cursor |
Time, Amplitude, Time and Amplitude, Value at cursor |
Zoom |
Zoom key enable display at individual grid area |
Calculation |
Addition, Subtraction, Multiplication, FFT(8k points maximum, RECTANGULAR, HANNING, FLATTOP) |
Rescaling / Unit conversion |
a*x+b(x: input voltage at User defined a and b) / Volt, Ampere, Watt, degree and unit-less |
Replay |
Automatic waveform recording upto 1,024waveforms, History Replayable |
Counter |
6-digit |
Interface (standard) |
USB 2.0(Host&Device), LAN(100Base-TX), GPIB(Factory option: DS-576) |
AUX Interface |
AUX connector for External options |
Waveform Data Storage |
UUSB memory for Binary, ASCII, Mathcad, Calculation(ASCII) & Calculation(Mathcad) |
Hardcopy Output |
Output form front panel USB port to USB memory in TIFF, BMP & PNG format or Output to PictBridge Printers |
Calibration signal output |
Square waveform at 1kHz, 3Vp-p |
Power / power consumption |
AC 90Vrms to 240Vrms, 47Hz to 63Hz, AC 90Vrms to 132Vrms, 380Hz to 420 Hz, 95VA max (60W max) |
Dimensions (mm) / Weight |
Approx. 330W × 190H ×124D / Approx. 3.7kg |
Environmental condition |
Performance guarantee temperature |
+10℃ to + 35℃ |
Operation temperature and humidity /
Altitude conditions |
0deg. to +40˚C at 5 to 80%(RH<=30˚C) and 55%RH or less at 40˚C non-condensation /
2,000meter or lower |
Accessory |
Probe(multi-channel), Power cord, Front panel cover, CD-ROM(Instruction Manual, Remote Control Manual), User's Guide |
Factory options |
AUX IO CH1/CH2 output
DS-577
(factory option) |
AUX IO1: Output of CH1 input signal with applied offset voltage, AUX IO2: Output of CH2 input signal with applied offset voltage |
AUX IO CH1/TRIG output
DS-578
(factory option) |
AUX IO1: Output of CH1 input signal with applied offset voltage,
AUX IO2: H-level pulse signal output occurs under the following conditions
・Output when triggered
・Output when Pass/Fail judgment result becomes Pass or Fail |
GPIB Interface
DS-576
(factory option) |
GPIB: IEEE488.2 (factory option) |
2 ways optional for Probe Power supply
DS-579 |
Our active probe power supply (2 systems) |