Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Thiết bị đo Isolation measurement system DM-8000H Iwatsu

Mã sản phẩm: DM-8000H
Sử dụng cho Model:
Hãng SX:
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng


Tên Sp: Isolation measurement system DM-8000H Iwatsu

Mã SP: DM-8000H

Hãng: Iwatsu

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm


Item DM-8000H

Transceiver card connection
Number of slots 6(Max.12 isolation units and/or acquisition units can be connected.)

Time axis
Sweep range 1 ns/div to 20 s/div
Clock accuracy 10 ppm
Acquisition mode Normal/peak

Trigger system
Trigger operation mode Auto, Normal, Single, Stop
Trigger source Up to 24 channels
Trigger type Edge or pulse width
Trigger delay Available

Interface
Ethernet port 3 port (10BASE-T/100BASE-TX/1000BASE-T)

Power supply unit
AC power 100 V to 240 V (50/60 Hz)
Power consumption 130 VA max

Mechanical unit
Dimensions and weight 132 (H) x 351 (W) x 420 (D) mm, Approx. 6.9 kg
Operating temperature 0 to +40°C
Performance guaranteed temperature 10 to +35°C

Accessories
LAN cable 1
Power supply cable 1
Operating manual CD-R (1)
Control software IS viewer DM-800 CD-R (1)

DM-900/DM-910L Isolation Unit and DM-400/L Acquisition Unit


Item DM-900, DM-900L DM-910, DM-910L DM-400, DM-400L

Signal input unit
Frequency Bandwidth
(-3 dB)
500 MHz
Bandwidth limiter 20 MHz, 100 MHz
Input impedance 1 Mohm // 16 pF 1 Mohm // 16 pF or 50 ohm
Maximum input voltage 400 Vmax (DC + AC peak <= 5 kHz) CAT I
Number of channels 2 (between channels are not isolated) 1 2 (Not isolated)
Input coupling GND/ DC 1 Mohm,
AC 1 Mohm
GND/ DC 1 Mohm GND/ DC 1 Mohm,
AC 1 Mohm, AC 50 ohm
Input sensitivity 2 mV/div to 10 V/div, 1-2-5 steps
CH1-MAIN: 50 mV/div to 5 V/div, 1-2-5 steps
CH2-ZOOM 2 mV/div to 1 V/div, 1-2-5 steps
2 mV/div to 10 V/div, 1-2-5 steps
Offset range 2 mV/div to 50 mV/div: ±1 V *1
100 mV/div to 500 mV/div : ±10 V *2
1 V/div to 10 V/div : ±100 V *3
CH1-MAIN: 50 mV/div to 500 mV/div: ±10 V *2
1 V/div to 5 V/div: ±100 V *3
CH2-ZOOM 2 mV/div to 20 mV/div: ±2 V *1
50 mV/div to 1 V/div: ±20 V *2
2 mV/div to 50 mV/div: ± 1 V *1
100 mV/div to 500 mV/div : ±10 V *2
1 V/div to 10 V/div : ±100 V *3
DC gain accuracy ± (1.5% + 0.5% of ful-scale)
Offset accuracy ± (1.0% + 0.5% of full-scale + X)
X: *1 1 mV, *2 10 mV, *3 100 mV
Probe sense 10:1, 100:1, 1000:1 (Auto detection/manual settings)
Sample rate 1 GS/s (2 GS/s during interleave)
Vertical axis resolution 8 bits
Maximum memory length DM-900: 500k points per channel
DM-900L: 16M points per channel
DM-910: 500k points per channel
DM-910L: 16M points per channel
DM-400: 500k points per channel
DM-400L: 16M points per channel

Trigger system unit
Trigger sources CH1, CH2 CH1-MAIN CH1, CH2
Trigger slope Positive / Negative
Coupling AC, DC, HFREJ, LFREJ
Level range 125% of full scale

Interface
Interface One set of three optical interfaces (optical fiber: 2 to 200 m) One set of electrical interfaces (specially designed cable: 2 or 5 m)

Power supply and battery unit
Internal battery 3 battery packs (unit can operate on one battery) -
Battery charging Can be charged by the main unit -
Battery charger Optional -
Power consumption 120 VAmax (when using AC power) 40 VAmax
Battery operation time Approx. 12 hours of continuous operation (when using 3 batteries) -
Battery charging time Approx. 6 hours -
AC power supply AC 100 to 240 (50/60 Hz)

Calibration signal
Calibration signal 0.6 V/6 V (switchable)

Mechanical unit
Dimensions (mm) 122.4 (H) x 258.4 (W) x 544 (D) 96.4 (H) x 171.6 (W) x 322.6 (D)
Weight Appro. 7 kg (excluding battery packs and accessories)
Battery pack weight: Approx. 660 g per pack
2.6 kg
Operating temperature 0 to +40°C
Performance guaranteed temperature +10 to +35°C

Accessories
Battery pack 3 -
Power supply cable 1

DM-600/DM-620/DM-630 Transceiver Card


Item DM-600 DM-620 DM-630
Number of isolation/acquisition units connected 2 (DM-900/L, DM-910/L) 1 (DM-900/L, DM-910/L) +1 (DM-400/L) 2 (DM-400/L)
Operation indicator Status display via LED
Mechanism Card inserted in main unit (DM-8000)
Operating temperature 0 to +40°C
Performance guaranteed temperature +10 to +35°C

IS Viewer DM-800 (supplied with the DM-8000H main unit)


* IS viewer is installed in the controlling computer (option) and is used to operate the isolation system and to monitor waveforms.

Item DM-800

Main function
Operations +, -, ×, ÷, |×|, |÷|, ∫, dy/dx
Parameter measurements Max, Min, p-p, Top, Base, Top-Base, RMS, CycleRMS, Mean, CycleMean, +/-Overshoot, TransitionTime, dv/dt, Freq, Period, +/-PulseCount, +/-PulseWidh, Duty, Integral, Integral(abs), Integral(pos), Integral(neg), Skew(%), Skew(Level)
Other functions XY display, FFT, Cursor, smoothing, channel deskewing, rescaling, offline viewer function
Saving waveforms CSV
Saving images BMP, PNG, Clipboard
Saving setup values With waveforms and without waveforms

Controlling computer
CPU Intel® Pentium®4 Processor or later
RAM 2 GB or larger
OS Windows® XP Professional SP3 *Note1
Windows® Vista Business SP2 *Note2
Display At least WXGA (1280 x 768 pixels) recommended
(SXGA (1280 x 1024 pixels) is required for full display.)


Bình luận