| ◆ leakage current detection unit |
| Monitoring the number of circuits |
2 (2-channel) |
| Detecting scheme |
CT clamp method |
| Current Range |
50/100/200/400 / 800mA total of five range |
| Measuring frequency |
50 / 60Hz |
| Detection accuracy |
Within ± 5% for each current set value (in standard CT) |
| Detection timed |
About 2 seconds |
| Return value |
80% ± 5% of the set current value (in standard CT) |
| Output signal adding time |
The output signal is ON 2 to 3 seconds output has returned. |
| AC conversion system |
Average value rectification (effective value calibration) |
| ◆ current transformer |
| CT Mado径 |
Fai22㎜ |
| Construction |
Split type ZCT |
| ◆ alarm output section |
| Output circuit number |
2 circuit |
| Output system |
Relay contact output (AC125V, 0.5A / DC24V, 1A) resistive load |
| ◆ General Specifications |
| Working voltage |
AC100V ± 10%, 50 / 60Hz |
| Power consumption |
2VA below |
| usage environment |
0 ~ 50 ℃, 85% RH or less (non-condensing) |
| Storage environment |