Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Thiết bị kiểm tra DRCT-1 Soukou

Mã sản phẩm: DRCT-1
Sử dụng cho Model:
Hãng SX: Soukou
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng

Operating voltage of the circuit breaker or the like of the DC operation AC AC100V power, possible to measure the operating time is. DC relay 50F, can test of 32,64P (64PB).


Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Specification


Use power AC100V 50 / 60Hz ± 10%
Voltage element output DC5 ~ 750V (continuously variable)
Output current 500mA
Output switching Test switch "ON" second-hand voltage and current output 
* 64PB output operation time measurement teeth, 0V scolded test voltage similar sudden change to another time wo measured masu. (P element output)
Current element output DC5 ~ 120V (continuously variable)
Output current 10A (continuous rating) 
15A (5 min rating) maximum output voltage of 100V
Output switching Voltage and current output at the test switch "ON" 
* 64PB output operation time measurement, we can measure the time that a sudden change in the test voltage from 0V. (B element output)
Output resistance switching Resistance switching for current adjustment 
and high range 20Ω low range 5Ω short 0Ω 
high-range 5A output (5 min rating) 
low range 10A output (5 min rating) 15A output (1 minute rating) 
short circuit 10A (continuous rating) 15A (5 min rating )
Voltage element voltmeter 750.0V (resolution 0.1V) 7 segment LCD
Measurement accuracy ± 0.5% rdg ± 5dgt
Sampling rate 2.5 times / sec.
Current element voltmeter 199.9V (resolution 0.1V) 7 segment LCD
Measurement accuracy ± 0.5% rdg ± 5dgt
Sampling rate 2.5 times / sec.
Current element ammeter 19.99A (resolution 0.01A) 7 segment LCD
Measurement accuracy ± 0.5% rdg ± 5dgt
Sampling rate 2.5 times / sec.
counter Measurement range 0 ~ 199.999sec resolution 01Ms 
200.00 ~ 1999.99Sec resolution 10ms (automatic carry)
Measurement accuracy 0.01% rdg ± 1dgt ± 5ms ± ⊿ t ⊿ t: 
stop signal Niyoru each error 
contact, DC voltage 
± voltage 
(05 voltage 
(10 voltage (20V ERROR) ± 1ms
Stop signal Contact a contact, b contact automatic detection 
voltage direct current, alternating both 10 ~ 220V applied, removed
Timer (B, P element common) Set time 0.001s ~ 9999h
Number of digits 4-digit
Output time error Maximum 30ms
Output contact (B, P element each output) Contact capacity AC / DC110V 0.1A
External dimensions 662 (W) × 247 (D) × 440 (H)
weight About 23kg
accessories Lead (power cord, auxiliary power cord, current element output code, voltage element output code, timed measurement code, earth code) 
lead storage bag 
photo MOS relay 
manual