Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Thiết bị kiểm tra máy cắt CBT-8T75VDM Soukou

Mã sản phẩm: CBT-8T75VDM
Sử dụng cho Model:
Hãng SX: Soukou
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng
Feature


■ possible 6CH timing measurement of the circuit breaker or the like of the DC operation 
■ turned on, the operating voltage of the cutoff can be measured 
■ current measurement function, there type CO characteristic features are marked with (CBT-8T75VDM) 
■ contact state can be determined in the lamp

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Specification


Use power DC110V ± 20%
Voltage output DC25 ~ 75V (continuously variable)
Output current 17A (0.2 seconds) 1A (Continuous)
Output control In "ON" switch, and output between the input -N. 
In "OFF" switch, output between switching -N.
Output voltage meter 199.9V (resolution 0.1V) 7-segment LED
Measurement accuracy ± 0.5% rdg ± 5dgt
Sampling rate 2.5 times / sec.
Contact measurement function Measurements CH 6CH
Measurement time 0 ~ 50/100/250 / 500ms ( resolution 0.1Ms) 
0 ~ 5000 / 20000Ms (resolution 2ms)
measurement error 0.01% rdg ± 0.3ms (resolution 0.1Ms) 
0.01 Pasento rdg ± 0.6Ms (resolution 2ms)
Detecting circuit Contact input detection voltage DC24V measure current up to 30mA
Record start condition Start a measurement when you press the "ON" or "OFF" of the voltage output operation
Contact status display function When the measured contact of the closed circuit condition, the lamp is lit
Noise mask function ON within measurement contact 3ms, when you repeat the OFF state, it does not record a change in the state of contact is regarded as noise.
CO characteristic function Operation "ON" in the state press the switch to "ON" by pressing the switch input voltage is output (measurement start), after the set time has elapsed from the time of any of the main contact is operated (on state), and outputs a switching voltage. 
* Measurement operation of the measuring time does not change anything.
Set time Measurement time 50 ~ 500ms range, 1 ~ 99ms (1ms unit) 
measurement time 5000 ~ 20000ms range, 10 ~ 990Ms 
(10Ms units)
Current measurement function Measurement range 0 ~ 20A (resolution 0.1A)
measurement error ± 1% rdg ± 2dgt
display 40-digit two-line LCD display
Print out output Built-in printer (paper width 80 mm)
External dimensions 250 (D) × 480 (W) × 360 (H)
weight About 10.7kg