Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Thiết bị kiểm tra relay DGR-3100CVK Soukou

Mã sản phẩm: DGR-3100CVK
Sử dụng cho Model:
Hãng SX: Soukou
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng

Feature


■ current, voltage, all phase meter precision class 0.5 meter adopted 
■ DGR-3100CVK of precision (0.5) class type

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Specification


Use power AC100V ± 10V 50 / 60Hz
Zero-phase voltage output (current) range AC25 / 250/500 / 1000V 25 / 250mA
capacity 50VA30 minute rating (25V range, 5VA) 
current output maximum load impedance about 85Ω
Indicating instrument Moving coil-shaped, with a 1.0 grade mirror
Output stability Each range ± 1%
Frequency stability ± 0.1% or less
Total distortion factor Less than 1%
Overcurrent protection Attenuation at about 110% of the rated capacity
Zero-phase current output range AC0.5 / 1.5 / 5 / 10A
capacity 0.5A maximum load impedance 12Ω (continuous) 
1.5A maximum load impedance 4Ω (continuous) 
5A maximum load impedance 12Ω (Continuous) 
10A maximum load impedance 0.6Ω (30 minute rating)
Indicating instrument Moving coil-shaped, with a 1.0 grade mirror
Output stability Each range ± 1%
Frequency stability ± 0.1% or less (output frequency set by the panel surface)
Total distortion factor Less than 1%
phase Adjustable range LEAD175 ° ~ 0 ~ LAG175 ° (fine adjustment range about 20 °)
Indicating instrument Moving-coil type ± 3 ° with mirror
Inertia output 0 ~ 999ms resolution 1ms ± 1ms (zero-phase voltage, control both the zero-phase current)
Test output Zero-phase voltage, the zero-crossing output (zero-phase current depends on the phase adjustment.)
VR test Voltage output method Using the zero-phase voltage output circuit, fine adjustment knob test voltage, the coarse adjustment knob to adjust the reference voltage.
Voltage switching time Switching by the toggle switch, it will switch within 1ms regardless of the switch operation.
counter 0 ~ 199.999sec resolution 1Ms 
200 ~ 1999.99Sec resolution 10ms (with automatic carry function)
Counter accuracy 0.01 Pasento rdg ± ± ± 1Dgt 5Ms ± ⊿T 
⊿T: each error of the stop signal 
contacts, DC voltage 1Ms ± 
AC voltage (5 ~ 10V) ± 5Ms 
AC voltage (10 ~ 20V) ± 2.5Ms 
AC voltage (more than 20V) ± 1ms 
self-power ± 3ms 
case of ※ stop due to self-supply, depends on the supply load state of the power supply (back electromotive force due to the rotation device, etc., the residual voltage of the capacitor, etc.).The above accuracy, power supply of the counter is the accuracy of to completely cut off.
Stop signal Contact: a contact, b contact automatic detection 
voltage: direct current, alternating current with 10 ~ 220V applied, remove 
the self-power: there is no power at the same time tester and the display time for about 5 minutes (the relay is operated, it is that the counter is stopped. ) 
* with automatic reset function
Auxiliary power AC100V, DC24V, DC48V, DC110V 
(AC100V is 500VA · DC output is 30W)
External dimensions 370 (D) × 585 (W) × 240 (H)
weight 21kg
accessories Test code set (with storage bag) owner manual case cover