| Model name |
AC36 series
|
| Housing φ |
37.5 mm
|
| Shaft Diameter |
6 mm (solid shaft)
|
| Flange type |
Pilot flange
|
| Protective structural axis (EN 60529 |
IP 64
|
| Protective structure housing (EN 60529) |
IP 64
|
| Maximum rotation speed |
10,000 rpm (continuous operation), 12,000 rpm (short time operation)
|
| Drive torque |
0.01 N · m
|
| Axial moment of inertia |
10 × 2.5 -6 Kgm2
|
| Vibration resistance (DIN EN 60068-2-6) |
100M / S 2 (10 ... 2000Hz)
|
| Impact resistance (DIN EN 60068-2-27) |
1000M / S 2 (6Ms)
|
| Operating temperature limit |
-25 to 100 ° C
|
| Storage temperature range |
-15 to 85 ° C
|
| Housing material |
aluminum
|
| mass |
Approximately 80 g (ST) / 130 g (MT)
|
| Connection |
Cable (Layout, Landscape)
|
| Power-supply voltage |
DC 5 V, -5% / + 10% or DC 7 to 30 V
|
| Maximum current consumption (no load) ST / MT |
50 mA (ST) / 100 mA (MT)
|
| Resolution Single Turn (ST) |
12 to 17 bit
|
| Resolution Multi-turn (MT) |
12 bit
|
| Output code |
Gray, binary
|
| Signal line (transmission form) |
Clock, Data (RS 422)
|
| Incremental output signal (option) |
Sin - Cos 1 Vpp
|
| Number of pulses |
2048
|
| Frequency at 3 dB attenuation |
500 kHz
|
| Alarm output |
SSI: Alarm bit (option), BiSS: Warning bit & alarm bit
|
| RoHS Directive |
Correspondence
|
| Option (see page 105) |
TC-1
|