1529 Chub-E4 Standards Thermometer

Mã sản phẩm: 1529
Sử dụng cho Model:
Hãng SX: Fluke
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

PRT / RTD Thermistor  Thermocouple 
Inputs  2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering;
PRT/thermistor channels accept 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types. (Support for C and U type thermocouples is available. Download the application note 
Temperature Range  –189 °C to 960 °C  –50 °C to 150 °C  –270 °C to 1800 °C 
Measurement Range  0 to 400 W 0 to 500 KW –10 to 100 mV 
Characterizations  ITS-90, IEC-751 (DIN “385”), Callendar-Van Dusen  Steinhart-Hart, YSI-400  NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial 
Temperature Accuracy (meter only)  ± 0.004 °C at –100 °C 
± 0.006 °C at 0 °C 
± 0.009 °C at 100 °C 
± 0.012 °C at 200 °C 
± 0.018 °C at 400 °C 
± 0.024 °C at 600 °C 
± 0.0025 °C at 0 °C 
± 0.0025 °C at 25 °C 
± 0.004 °C at 50 °C 
± 0.010 °C at 75 °C 
± 0.025 °C at 100 °C 

 

                    Ext. RJC     Int. RJC 
B at 1000 °C  ± 0.6 °C  ± 0.6 °C
E at 600 °C  ± 0.07 °C  ± 0.25 °C
J at 600 °C  ± 0.1 °C  ± 0.35 °C
K at 600 °C  ± 0.15 °C  ± 0.4 °C
N at 600 °C  ± 0.15 °C  ± 0.3 °C
R at 1000 °C  ± 0.4 °C  ± 0.5 °C
S at 1000 °C  ± 0.5 °C  ± 0.6 °C
T at 200 °C  ± 0.1 °C  ± 0.3 °C
Temperature Resolution  0.001 °  0.0001 °  0.01 to 0.001 ° 
Resistance/Voltage Accuracy  0 W to 20 W:  ± 0.0005W 
20 W to 400 W:  ± 25 ppm of rdg. 
0 W to 5 KW:  ± 0.5 W 
5 KW to 200 KW:  ± 100 ppm of rdg. 
200 KW to 500 KW ± 300 ppm of rdg. 
–10 to 50 mV:  ± 0.005 mV 
50 to 100 mV:  ± 100 ppm of rdg. 
Internal RJC: ± 0.25 °C) 
Operating Range  16 °C to 30 °C 
Measurement Interval  0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval 
Excitation Current  1 mA, reversing  2 and 10 µA, automatically selected  n/a 
Display  33 x 127 mm (1.3 x 5 in) backlit LCD graphical display 
Display Units  °C,  °F, K, W, KW, mV 
Data Logging  Up to 8,000 time- and date-stamped measurements can be logged 
Logging Intervals  0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes 
Averaging  Moving average of most recent 2 to 10 readings, user selectable 
Probe Connection  Patented DWF Connectors accept mini spade lug, bare-wire, or mini banana plug terminations  Universal receptacle accepts miniature and standard TC connectors 
Communications  RS-232 included, IEEE-488 (GPIB) optional 
AC Power  100–240 V ac, 50-60 Hz, 0.4 A 
DC Power  12–16 VDC, 0.5 A (battery charges during operation from 14.5 to 16V DC, 1.0A) 
Battery  NiMH, 8 hours of operation typical without backlight, 3 hours to charge, 500 cycles 
Size (HxWxD)  102 x 191 x 208 mm (4.0 x 7.5 x 8.2 in) 
Weight  2 kg (4.5 lb) 
Calibration  Accredited NIST-traceable resistance calibration and NIST-traceable voltage calibration provided 