| Operating Conditions | 
        
            | Measurement medium | Water or other conductive liquids Minimum conductivity:20 μS/cm
 | 
        
            | Medium temperature | In combination with a PVC fitting: 0 to +50°C In combination with a PE fitting: 0 to +70°C
 In combination with a PP fitting: 0 to +80°C
 In combination with a stainless steel fitting:-15 to +150°C
 | 
        
            | Ambient temperature | -10 to +60°C operating temperature -20 to +60°C storage temperature
 | 
        
            | Tube diameter | For diameters DN15 to DN 400. Only in combination with fittings as per Data Sheet 406090.
 | 
        
            | System pressure | In combination with a PVC or PE fitting: 
  | 
        
            | Minimum inlet and outlet distances
 | See illustrations on page 5/5 | 
        
            | Relative humidity | < 80%, non-condensing | 
        
            | Enclosure protection | IP65 | 
        
            | EMC | EN 50081-1, EN 61000-6-2 | 
        
            | Safety | EN 61010-1 | 
        
            | Vibration | EN 60068-2-6 | 
        
            | Impact | EN 60068-2-27 | 
        
            | Measuring range | 
        
            | Flow speed | 0.2 to 10 m/s | 
        
            | Accuracy (With a flow speed
 of from 1 to 10 m/s
 and a medium
 temperature in the range
 from -15 to 70°C)
 | With standard K factor: ≤ ± 4% of measured value After teach-in: ≤ ± 2% of measured value
 | 
        
            | Linearity | ≤ ± 1% of measured value + 0.1% of measurement range end | 
        
            | Repeatability | ≤ ± 0.25% of measured value | 
        
            | Materials | 
        
            | Housing, cover, nut | PPA | 
        
            | Screws, seal, cable gland | Sensor: stainless steel, EPDM, PA | 
        
            | Parts in contact with medium
 | Sensor: stainless steel 1.4404/316L, FKM, PEEK Fitting: see data sheet 406090
 | 
        
            | Electrical data | 
        
            | Power supply voltage | DC 18 to 36 V, reverse polarity protected | 
        
            | Power consumption | ≤ 220 mA | 
        
            | Output | Current: 4 to 20 mA, three wires Loop resistance: max. 1100 Ω at 36 V DC or max. 330 Ω at 18 V DC
 Frequency pulse: 0 to 240 Hz
 Clock ratio: 50%, ≤ 100 mA, protected against short circuit and reverse polarity
 Relay: 3 A, 250 VAC, changeover contact
 Alarm: when exceeding scale value: 22 mA or 256 Hz
 Device error: 22 mA or 0 Hz
 | 
        
            | Cable gland | M20 x 1.5 | 
        
            | Series terminals | for lines with cross-section up to 0.75 mm2 |