- Technical Specifications
Parameter |
Value |
Supply voltage single-phase alternating current, V |
230 ± 23 |
Frequency, Hz |
50 ± 2 |
Maximum power consumption, kVA, max |
3 |
Highest output voltage, kV: |
- AC |
50 |
- DC |
70 |
Highest output current, mA:
|
- on AC voltage
|
44
|
- on DC voltage
|
14
|
Reduced voltage error, %, max: |
- AC voltage from 2 kV to 50 kV
|
± 3 |
- DC voltage from 2 kV to 70 kV |
± 3
|
Reduced current error, %, max:
|
- AC from 1,0 mA to 45,0 mA
|
± 3 |
- DC from 0,5 mA to 14,5 mA
|
± 3
|
Maximum current threshold on the high-voltage side, mA, max: |
- AC voltage |
45 |
- DC voltage |
14.5 |
Control Unit dimensions, mm, max |
349 × 256 × 240
|
Control Unit Weight, kg, max |
14 |
High Voltage Unit dimensions, mm, max |
360 × 500 × 310 |
High Voltage Unit weight, kg, max |
35 |
lifespan, years, avg |
10 |
- Operating Conditions
The device is designed for an indoors operation under the following conditions:
Condition |
Value |
Air temperature, °С |
from -10 to +40
|
Relative humidity, %, up to
|
85 at +25 °С |
Atmospheric pressure, kPa (mm hg)
|
84,0 – 106,7 (630 – 800) |
-
|