MAIN FEATURES  
DC cable testing up to 80 kV;
Converting high-resistive cable faults into lowresistive with a use of burn generator;
Surge energy up to 2400 J;
Precise fault prelocating using Time‑Domain Reflectometer RIF‑9;
Cable route tracing with a use of 200 W lowfrequency generator and receiver;
Precise pinpointing using a surge wave generator with a ground microphone.
 
 
ADVANTAGES 
Easy user friendly interface;
High safety level;
Multistep self fault protection;
Flexible auxiliary equipment integration.
 
 
    
        
            | Parameter | 
            Value | 
         
        
            | GENERAL parameter | 
         
        
            | Input voltage, V | 
            230 ± 23 | 
         
        
            | Frequency, Hz | 
            50 ± 1 | 
         
        
            | Power consumption, kVA, max | 
            2.0 (3.5 for 40A burn generator) | 
         
        
            | TEST MODE | 
         
        
            | Output DC voltage range, kV | 
            0 – 80  
             | 
         
        
            | Output DC current range, mA | 
            0 – 580  
             | 
         
        
            | BURN MODE | 
         
        
            Output DC voltage range, kV 
             | 
            0 – 20 
             | 
         
        
            | Output DC current range, A | 
            0 – 40 
             | 
         
        
            | SURGE MODE | 
         
        
            | DC voltage ranges, kV | 
            4 / 8 / 16 / 32 
             | 
         
        
            | Output energy, J, max | 
            2560 (at each range) | 
         
        
            | Timer set (automatic surge mode), seconds | 
            3 – 15 
             | 
         
        
            | Manual single surge | 
             yes | 
         
        
            | Flexible voltage change during automatic operation | 
             yes | 
         
        
            Pinpointing with an acoustic receiver 
             | 
             yes | 
         
        
            | PRELOCATION MODE | 
         
        
            | Methods | 
            TDR / Arc reflection / Impulse current / Voltage coupling / Arc reflection + burn | 
         
        
            | Automatic distance measuring | 
            yes | 
         
        
            | Saving cable parameters into Reflectometer non‑volatile memory | 
            yes | 
         
        
            | Saving reflectograms either to Reflectometer non-volatile memory or USB flash drive | 
            yes | 
         
        
            | CABLE TRACING MODE | 
         
        
            | Cable tracing using 200W audio-frequency generator with frequencies 491/ 982/ 8440 Hz with a receiver | 
            yes | 
         
    
  
                             |