- Technical Specifications
Parameter |
HVTS-HP
70/55-7,5 (17,5) |
HVTS-HP
70/100-7,5 (17,5) |
HVTS-HP
100/100-7,5 (17,5) |
HVTS-HP
140/100-7,5 (17,5) |
Output test AC voltage range, kV |
0.5 – 55 |
1 – 100 |
Output test DC voltage range, kV |
0.5 – 70 |
1 – 100 |
1 – 140 |
Output test AC current, mA, max |
130 (300) |
75 (175) |
Output test DC current, mA, max |
90 (200) |
30 (65) |
40 (90) |
55 (125) |
Output AC voltage measuring range, kV
|
3 – 55 |
3 – 100 |
Output DC voltage measuring range, kV
|
3 – 70 |
3 – 100 |
3 – 140 |
Output AC current measuring range, mA |
1 – 130
(1 – 300)
|
1 – 75 (1 – 175) |
Output DC current measuring range, mA |
1 – 90
(1 – 200)
|
1 – 30
(1 – 65)
|
1 – 40
(1 – 90)
|
1 – 55
(1 – 125)
|
Measuring accuracy |
3 % (of full scale) |
Supply voltage, V |
220 ± 22 |
Frequency, Hz |
50 ± 1 |
In parentheses are the parameters for the performance of 17.5 kVA version.
- Operating Conditions
The device is designed for an indoors operation under the following conditions:
Condition |
Value |
Air temperature, °С |
from -10 to +40
|
Relative humidity, %, up to
|
80 at +25° С |
Atmospheric pressure, kPa (mm hg)
|
84,0 – 106,7 (630 – 800) |
|