The quality of rubber gloves is tested by applying high AC voltage of 9300 V at 50 Hz to them. 
Rubber gloves tester SVS-12 provides the following: 
    - Automatic discarding of those gloves, where leakage current is over 9 mA;
 
    - Automatic switching off the high voltage if the top lid is opened during the testing process;
 
    - Automatic filling gloves with water before testing;
 
    - Automatic delay that allows all water to drip from taps before applying testing voltage;
 
    - Automatically set time necessary for full test of each glove;
 
    - Visual control of the value of the test voltage and leakage current for each individual glove;
 
    - Audio signalling on the overall testing progress as well as audio indication of those gloves which failed the testing.
 
 
The tester SVS-12 allows simultaneous testing of up to 12 gloves. 
 
    - Technical Specifications
 
    
    
    
        
            
                | Parameter | 
                Value | 
             
            
                Single-phase AC power supply voltage, V 
                 | 
                220 ± 22 | 
             
            
                | Frequency, Hz | 
                50 ± 1 | 
             
            
                | Power consumption, VA, max | 
                1500 | 
             
            
                Test Mode  
                 | 
                Testing Lamp (100V) | 
                 Bath | 
             
            
                | Minimum RMS value of test voltage, kV | 
                0,02 | 
                1,0 | 
             
            
                | Maximum RMS value of test voltage, kV | 
                0,1  
                 | 
                10 | 
             
            
                | Reduced error voltage measurement, % | 
                ± 3 | 
                ± 3 | 
             
            
                | Minimum measurement of leakage current, mA | 
                not measured | 
                0,3 | 
             
            
                | Mmaximum measured leakage current, mA | 
                - | 
                9 | 
             
            
                | Reduced error of current measurement, % | 
                - | 
                ± 3 | 
             
            
                | Quantity of simultaneous test of gloves on the bench pieces | 
                12 | 
             
            
                | Tthe overall cycle time for batch test gloves, min. | 
                2 | 
             
            
                | Dimensions of the control unit, mm, max | 
                 316×187×132  | 
             
            
                | Ddimensions rack glove, mm, max | 
                 2015×876×1112  | 
             
            
                | Weight control unit, kg, max | 
                3 | 
             
            
                | Weight rack glove, kg, max | 
                 300  | 
             
            
                | Lifespan, years, avg | 
                10  
                 | 
             
            
                | Degree of protection of electrical equipment from the effects of the environment stand IR30 | 
                GOST 14255-69 | 
             
        
     
     
     
 
 
 
                             |