The quality of rubber gloves is tested by applying high AC voltage of 9300 V at 50 Hz to them.
Rubber gloves tester SVS-12 provides the following:
- Automatic discarding of those gloves, where leakage current is over 9 mA;
- Automatic switching off the high voltage if the top lid is opened during the testing process;
- Automatic filling gloves with water before testing;
- Automatic delay that allows all water to drip from taps before applying testing voltage;
- Automatically set time necessary for full test of each glove;
- Visual control of the value of the test voltage and leakage current for each individual glove;
- Audio signalling on the overall testing progress as well as audio indication of those gloves which failed the testing.
The tester SVS-12 allows simultaneous testing of up to 12 gloves.
- Technical Specifications
Parameter |
Value |
Single-phase AC power supply voltage, V
|
220 ± 22 |
Frequency, Hz |
50 ± 1 |
Power consumption, VA, max |
1500 |
Test Mode
|
Testing Lamp (100V) |
Bath |
Minimum RMS value of test voltage, kV |
0,02 |
1,0 |
Maximum RMS value of test voltage, kV |
0,1
|
10 |
Reduced error voltage measurement, % |
± 3 |
± 3 |
Minimum measurement of leakage current, mA |
not measured |
0,3 |
Mmaximum measured leakage current, mA |
- |
9 |
Reduced error of current measurement, % |
- |
± 3 |
Quantity of simultaneous test of gloves on the bench pieces |
12 |
Tthe overall cycle time for batch test gloves, min. |
2 |
Dimensions of the control unit, mm, max |
316×187×132 |
Ddimensions rack glove, mm, max |
2015×876×1112 |
Weight control unit, kg, max |
3 |
Weight rack glove, kg, max |
300 |
Lifespan, years, avg |
10
|
Degree of protection of electrical equipment from the effects of the environment stand IR30 |
GOST 14255-69 |
|