The installation allows testing: 
    - Rubber dielectric gloves;
 
    - Rubber dielectric boots;
 
    - Insulating materials on the DIY instruments (screw drivers, cutting pliers, etc.).
 
 
Equipment included in the SVS-50C package could be used for testing insulators with AC current (cable sheath, etc.). 
 
 
    - Technical Specifications
 
     
    
    
    General SVS-50C specifications: 
     
     
     
    - Operating Conditions
 
    
    
    The device is designed for an indoors operation under the following conditions: 
    
     
        
            
                | Condition | 
                Value | 
             
            
                | Air temperature, °С | 
                from +10 to +35 
                 | 
             
            
                Relative humidity, %, up to 
                 | 
                80 at +20 °С | 
             
            
                Atmospheric pressure, kPa (mm hg) 
                 | 
                84,0 – 106,7 (630 – 800) | 
             
        
     
     
     
 
    
        
            | Characteristic | 
            Value | 
         
        
            | Single-phase AC power supply voltage, V | 
            220±22 | 
         
        
            | Power supply frequency, Hz | 
            50±2 | 
         
        
            | Reduced error of voltage measurements in the range from 20 to 100 V, % | 
            ±3 | 
         
        
            | Reduced error of voltage measurements in the range from 1 to 6.5 kV, % | 
            ±3 | 
         
        
            | Reduced error of voltage measurements in the range from 6.5 to 15 kV, % | 
            ±3 | 
         
        
            | Reduced error of voltage measurements in the range from 10 to 50 kV, % | 
            ±3 | 
         
        
            | Reduced error of current measurements, % | 
            ±3 | 
         
        
            | Maximum consumed power, kW | 
            0,9 | 
         
        
            | Lifespan, years, avg | 
            10 | 
         
    
 
  
Test basin specifications: 
    
        
            | Characteristic | 
            Value | 
         
        
            Maximum voltage, kV 
             | 
            15 | 
         
        
            | Range of measurements of leakage currents, mA | 
            0.3-7.5 | 
         
        
            | Number of spaces of test subjects | 
            4 | 
         
        
            | Dimensions, mm, max | 
            700х795х865 | 
         
        
            | Net weight in dry condition, kg, max | 
             30 | 
         
    
 
  
Control unit specifications: 
    
        
            | Characteristic | 
            Value | 
         
        
            Consumed power, W, max 
             | 
            20 | 
         
        
            | Dimensions, mm, max | 
            316х187х132 | 
         
        
            | Net weight, kg, max | 
            3 | 
         
    
 
  
Measuring unit specifications: 
    
        
            Characteristic 
             | 
            Value 
             | 
         
        
            | Power consumption measuring unit + BVI, VA, max | 
            2000 | 
         
        
            Dimensions, mm, max 
             | 
            330х500х380 
             | 
         
        
            | Net weight, kg, max | 
            27 | 
         
    
 
  
High voltage unit BVI-50 specifications: 
    
        
            | Characteristic | 
            Value | 
         
        
            Range of leakage current measurements, mA 
             | 
            0.3...10.0 | 
         
        
            Maximum voltage, kV 
             | 
            50 | 
         
        
            | Dimensions, mm, max | 
            270×230×370 | 
         
        
            | Net weight, kg, max | 
            20 | 
         
    
  
                             |