- Technical Specifications
Parameter |
Value |
Supply voltage single-phase AC current, V
|
220 ± 15 |
Frequency, Hz |
50 ± 1 |
Maximum output current at AC 220 V, kA
|
6,4 |
Measurement range test current, kA |
1 ... 6 |
Measurement range test current, A |
100 ... 999 |
Test current supply time measurement range, s |
1 ... 999 |
Test current supply time measurement range, ms |
50 ... 990 |
Reduced error of the test current measurement, % max |
3 |
Absolute error of the current flowing time and the switching off time measurement in the range from 50 ms to 990 ms, ms, max |
20 |
Reduced error of the current flowing time and the switching off time measurement in the range from 1 s to 7200 s, %, max |
3 |
Continuous running time under the maximum current, s, min |
30 |
Highest power consumption, kW, max
|
33 |
Weight control unit, kg, max (no flexible busbars) |
47 |
Overall dimensions, mm, max |
535×358×200
|
Lifespan, years, avg |
10 |
- Operating Conditions
The device is designed for an indoors operation under the following conditions:
Condition |
Value |
Air temperature, °С |
from -35 to +35
|
Relative humidity, %, up to
|
80 at +20° С |
Atmospheric pressure, kPa (mm hg)
|
84,0 – 106,7 (630 – 800) |
-
|