Technical Specifications
-
Parameter |
Value |
Supply voltage 3-phase AC (50 Hz), V |
380 ± 38 |
Consumption power, kW∙A, max |
50 |
Continuous operation at maximum capacity, min, max |
20
|
Break after continuous use, min, min
|
40 |
Output power, kW∙A |
750 |
Capacitance range of objects test, uF |
0,01 - 1,5 |
Q-factor, min |
50 |
Greatest operating voltage AC test mode stator winding, kV |
35 |
Greatest operating voltage AC test mode trunking, kV |
70 |
Greatest operating voltage of the rectified current-leakage test, kV |
100 |
Reduced error measuring current and voltage, max, %
|
3 |
Threshold protection high-voltage side, A
|
25 |
Threshold protection low-voltage side, no more, A
|
120 |
Dimensions L × W × H, mm |
2900×2100×2300 |
Warranty life, h
|
1200 |
Weight, kg, no more
|
3000 |
- Operating Conditions
The device is designed for an indoors operation under the following conditions:
Condition |
Value |
Air temperature, °С |
from +1 to +35
|
Relative humidity, %, up to
|
80 at +25 °С |
Atmospheric pressure, kPa (mm hg)
|
84,0 – 106,7 (630 – 800) |
|