Technical Specifications 
    - 
    
    
        
            
                | Parameter  | 
                 Value  | 
             
            
                | Supply voltage 3-phase AC (50 Hz), V | 
                380 ± 38 | 
             
            
                | Consumption power, kW∙A, max  | 
                50 | 
             
            
                | Continuous operation at maximum capacity, min, max   | 
                20 
                 | 
             
            
                Break after continuous use, min, min  
                 | 
                40 | 
             
            
                | Output power, kW∙A  | 
                750 | 
             
            
                | Capacitance range of objects test, uF | 
                0,01 - 1,5 | 
             
            
                | Q-factor, min | 
                50 | 
             
            
                | Greatest operating voltage AC test mode stator winding, kV  | 
                35 | 
             
            
                | Greatest operating voltage AC test mode trunking, kV  | 
                70 | 
             
            
                | Greatest operating voltage of the rectified current-leakage test, kV  | 
                100 | 
             
            
                Reduced error measuring current and voltage, max, %  
                 | 
                3 | 
             
            
                Threshold protection high-voltage side, A  
                 | 
                25 | 
             
            
                Threshold protection low-voltage side, no more, A  
                 | 
                120 | 
             
            
                | Dimensions L × W × H, mm  | 
                2900×2100×2300 | 
             
            
                Warranty life, h  
                 | 
                1200 | 
             
            
                Weight, kg, no more  
                 | 
                 3000  | 
             
        
     
     
     
     
    - Operating Conditions
 
    
    
    The device is designed for an indoors operation under the following conditions: 
    
        
            
                | Condition | 
                Value | 
             
            
                | Air temperature, °С | 
                from +1 to +35 
                 | 
             
            
                Relative humidity, %, up to 
                 | 
                80 at +25 °С | 
             
            
                Atmospheric pressure, kPa (mm hg) 
                 | 
                84,0 – 106,7 (630 – 800) | 
             
        
     
     
     
 
 
                             |