Technical Specifications 
 
 
    
        - 
        
        
            
                
                    | Parameter | 
                    Value  | 
                 
                
                    | Supply voltage 3-phase AC (50 Hz), V | 
                    380 ± 38 | 
                 
                
                    | Consumption power, kV∙A, max  | 
                    50 | 
                 
                
                    | Continuous operation at maximum capacity, min, max   | 
                    20 
                     | 
                 
                
                    Break after continuous use, min, min  
                     | 
                    40 | 
                 
                
                    | Output power, kV∙A  | 
                    500 | 
                 
                
                    | Capacitance range of objects test, uF | 
                    0,01 – 0,7 | 
                 
                
                    | Q-factor, min | 
                    40 | 
                 
                
                    | Greatest operating voltage AC test mode stator winding, kV  | 
                    42 | 
                 
                
                    | Greatest operating voltage AC test mode trunking, kV  | 
                    55 | 
                 
                
                    | Greatest operating voltage of the rectified current-leakage test, kV  | 
                    70 | 
                 
                
                    Reduced error measuring current and voltage, max, %  
                     | 
                    3 | 
                 
                
                    Threshold current protection high-voltage side, A  
                     | 
                    10 | 
                 
                
                    Threshold protection low-voltage side, max, A  
                     | 
                    80 | 
                 
                
                    | Dimensions L × W × H, mm  | 
                    1970 × 1570 × 2200 
                     | 
                 
                
                    Warranty life, h  
                     | 
                    1200 | 
                 
                
                    Weight, kg, max 
                     | 
                    3500 | 
                 
            
         
         
         
         
        - Operating Conditions
 
        
        
        The device is designed for an indoors operation under the following conditions: 
        
            
                
                    | Condition | 
                    Value | 
                 
                
                    | Air temperature, °С | 
                    from +1 to +35 
                     | 
                 
                
                    Relative humidity, %, up to 
                     | 
                    80 at +25 °С | 
                 
                
                    Atmospheric pressure, kPa (mm hg) 
                     | 
                    84,0 – 106,7 (630 – 800) | 
                 
            
         
         
         
     
    - 
    
    
 
    - 
    
    
 
  
                             |