Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Water Auto Analyer Other automatic Analyzer - Humas

Mã sản phẩm: Water Auto Analyer
Sử dụng cho Model:
Hãng SX: Humas
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng

Water Auto Analyer

Maker : Humas

Yêu Cầu Giá Tốt

Thông tin sản phẩm

Water Auto Analyer

Maker : Humas

- Wide application range : filtration plants, water treatment plants, boiler water, etc.

- Various external output signals: alarm warning, under, calibration, equipment trouble, external pump in operation, etc.

- Semi-permanent use as LED light source

- Auto start function after black out, remote control (possible)

>>FE 4000 (Automatic iron analyzer)
IItems for measurement Total Iron
Measuring range Low density : 0.5~100ppb / High density : 0.05~5ppm
Precision ±5
Resolution Low density : 0.1ppb / high density : 0.01ppm
Measuring cycle Low density : 6 min./cycle, high density : 3 min./cycle
Flow rate of sample water 200~500mL/min (250ml/min.recommended)
Reagent replacement cycle Four weeks
Data output 4~20mA, RS-485
External output Alarm, equipment trouble, under calibration,
external pump in operation, remote control
Power AC 220V, 60Hz (AC 110V Option)
Applicable environment Non-vibration, temperature : 5~40℃,
humidity : 90% at 40℃
>>AL4000 (Automatic aluminum analyzer)
IItems for measurement Aluminum
Measuring range 0.01 ~ 0.3ppm
Precision ±10% of F.S
Resolution 0.003/0.01Abs
Measuring cycle 10 min.
Flow rate of sample water 200~500ml/min (250ml/min.recommended)
Reagent replacement cycle Four weeks
Data output 4~20mA, RS-485
External output Alarm, equipment trouble, calibration, external
pump in operation, remote control
Power AC 220V, 60Hz (AC 110V Option)
Applicable environment Non-vibration, temperature : 5~40℃,
humidity : 90% at 40℃
>>SI 4000 (Automatic silica analyzer)
IItems for measurement Silica
Measuring range 1~4000ppb as SiO2
Precision ±5
Resolution Low density : 1ppb
Measuring cycle 10 min./cycle
Flow rate of sample water 200~500mL/min (250ml/min.recommended)
Reagent replacement cycle Eight weeks
Data output 4~20mA, RS-485
External output Alarm, equipment trouble, calibration,
external pump in operation, remote control
Power AC 220V, 60Hz (AC 110V Option)
Applicable environment Non-vibration, temperature : 5~40℃,
humidity : 90% at 40℃
>>CU 4000 (Automatic copper analyzer)
IItems for measurement Copper
Measuring range 0.1 ~ 10ppm
Precision ±5% of F.S
Resolution 0.006/0.001Abs
Measuring cycle 5 min.
Flow rate of sample water 200~500mL/min (250ml/min.recommended)
Reagent replacement cycle Four weeks
Data output 4~20mA, RS-485
External output Alarm, equipment trouble, calibration,
external pump in operation, remote control
Power AC 220V, 60Hz (AC 110V Option)
Applicable environment Non-vibration, temperature : 5~40℃,
humidity : 90% at 40℃

Bình luận