| Voltage Range |
0-10000 VAC 0-14000 VDC |
| Current Range |
3 mA at 10 KVAC 1 mA at 14 KVDC |
| Input Voltage Requirements |
108-132 V, 50 /60 Hz, 2A max |
| Fuse Requirements |
120 VAC |
| Arc Detect |
Separate high Frequency circuit |
| Leakage Detect |
Separate Low frequency circuit |
| Ground Continuity |
N/A |
| Ground Continuity Current |
N/A |
| Test Time Range |
1 - 60 seconds |
| Ramp time Range |
1 - 5 Seconds |
| Voltage Meter Accuracy |
± 2 % |
| Current Meter Accuracy |
±0.1 mA |
| Resistance measure Range |
N/A |
| Resistance auto offset Range |
N/A |
| Resistance Measure Accuracy |
N/A |
| HV shutdown by Ground Fail |
N/A |
| Duty cycle |
100% |
| Discharge Time |
(Resistive Load) |
| Transformer Output |
< 500 VAC |
| Pass/Fail Repeatability |
± 3 % |
| Output connector |
High Voltage Jack |
| Display |
4 digits LED display |
| Test indicator |
Led indicators |
| Failure Indicator |
Led indicators and buzzer |
| Programable |
No |
| PLC Interface |
No |
| TestLink |
N/A |
| Testminder |
No |
| Voltage Hold on failure |
Available |
| Top Mounted handle |
No |
| Test Defeat |
Ramp Time, Test Time and Breakdown Fail |
| Autoreset on Pass |
Optional |
| Operation Temperature |
15 - 40 °C |
| Relative Humidity Range |
0 - 90 % Non-condensing |
| Dimensions |
17" Wide x 5 High x 16.75 " Deep |
| Weight |
31 lB |
| Calibration |
One year calibration Certificate |
| Test Cords |
Return lead, High Voltage Test Lead, Power cord |
| HTS/Schedule B |
9030.39.0100 |
| ECCN |
3B992 |