Features
AC output: up to 10,000 V.
Microcontroller Technology, one button test, easy to setup, LED's indicate test progress. Upon failure, buzzer sounds and testing is terminated.
Output voltage, leakage current limit and test duration are controlled from the front panel.
Arc detection and test timer are defeatable.
Ergonomically designed for safety, speed and efficiency.
Designed for product development and laboratory use.
Cables, manual and calibration certificate included.
One year calibration cycle.
One year warranty.
Specifications |
Voltage Test Type |
AC |
Output Voltage |
0 - 10,000VAC |
Leakage Current Adjustment |
1 - 20 mA AC, increments of 0.1 mA |
Input Voltage |
120 V *different line voltages available |
Frequency |
50/60 Hz |
Fuse |
250 VAC 2 A Slow Blow |
Breakdown Detect |
Independent High Frequency Circuit |
Transformer Power |
< 500 VAC |
Leakage Current Detect |
Independent Low Frequency Circuit |
Test Time Range |
1 - 60 seconds |
Displays |
4 Digits LED Display (Voltage), 3 Digits LED Display (Current) |
Voltage Meter Accuracy |
± 2 % |
Current Meter Accuracy |
± 0.1 mA from 1 – 17mA ± 0.2 mA from 17 – 20mA |
Duty Cycle |
100 % |
Operation Temperature |
15 - 40 °C |
Relative Humidity Range |
0 - 90 % Non-Condensing |
General |
Dimensions |
17” Wide x 6” High x 17” Deep |
Weight |
32 lbs |
Product Package |
HT-10KVPac 20mA -HT-10KVPac 20mA Product Manual-18 AWG Test Lead (Black)-18 AWG High Voltage Test Lead (Red)-NIST Traceable Calibration Certificate to ANSI Z540 |
Options |
(xxx) Different Line Voltages |
Replace on the part number xxx-for 100, 110, 220, 230 or 240 depending the-line voltage. (120V for standard configuration). |
(XI) Safety Interlock |
Two position terminal block on rear panel-must be shorted for high voltage operation. |
(VF) Voltage on Failure |
If failure as Excess Leakage or Hipot-Fail happens, it will terminate the test and-the front voltage display-will hold the last voltage reading. |
(AR) Auto Reset on Pass |
Resets the tester after a few seconds only on passing test condition. |
(ZOS) Zero Voltage Start |
Voltage adjust knob must be to minimum position to allow start the test cycle.(RI) Relay Isolated Remote |
Interface |
It allows the interface with a PLC or other machine using relay closures. This option allows isolation between the PLC and the Hipot tester. |
Safety |
Visual Indicator of Voltage |
Provided by front panel meter, directly connected to high voltage output. |
Output |
Failure Indicator |
Audible, provided by buzzer.-isual, Provided by red LED's.-Test automatically terminated on failure. |
Leakage Test |
Provided, 1 mA AC factory set pass/fail point, user adjustable. |