Compliance HT-10KVPac-20mA-I HT-10KVPAC

Mã sản phẩm:
Sử dụng cho Model:
Hãng SX: Compliance
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Features

AC output: up to 10,000 V.
Microcontroller Technology, one button test, easy to setup, LED's indicate test progress. Upon failure, buzzer sounds and testing is terminated.
Output voltage, leakage current limit and test duration are controlled from the front panel.
Arc detection and test timer are defeatable.
Ergonomically designed for safety, speed and efficiency.
Designed for product development and laboratory use.
Cables, manual and calibration certificate included.
One year calibration cycle.
One year warranty.


Specifications
Voltage Test Type AC
Output Voltage 0 - 10,000VAC
Leakage Current Adjustment 1 - 20 mA AC, increments of 0.1 mA
Input Voltage 120 V *different line voltages available
Frequency 50/60 Hz
Fuse 250 VAC 2 A Slow Blow
Breakdown Detect Independent High Frequency Circuit
Transformer Power < 500 VAC
Leakage Current Detect Independent Low Frequency Circuit
Test Time Range 1 - 60 seconds
Displays 4 Digits LED Display (Voltage), 3 Digits LED Display (Current)
Voltage Meter Accuracy ± 2 %
Current Meter Accuracy ± 0.1 mA from 1 – 17mA ± 0.2 mA from 17 – 20mA
Duty Cycle 100 %
Operation Temperature 15 - 40 °C
Relative Humidity Range 0 - 90 % Non-Condensing
General
Dimensions 17” Wide x 6” High x 17” Deep
Weight 32 lbs
Product Package HT-10KVPac 20mA -HT-10KVPac 20mA Product Manual-18 AWG Test Lead (Black)-18 AWG High Voltage Test Lead (Red)-NIST Traceable Calibration Certificate to ANSI Z540
Options
(xxx) Different Line Voltages Replace on the part number xxx-for 100, 110, 220, 230 or 240 depending the-line voltage. (120V for standard configuration).
(XI) Safety Interlock Two position terminal block on rear panel-must be shorted for high voltage operation.
(VF) Voltage on Failure If failure as Excess Leakage or Hipot-Fail happens, it will terminate the test and-the front voltage display-will hold the last voltage reading.
(AR) Auto Reset on Pass Resets the tester after a few seconds only on passing test condition.
(ZOS) Zero Voltage Start Voltage adjust knob must be to minimum position to allow start the test cycle.(RI) Relay Isolated Remote
Interface It allows the interface with a PLC or other machine using relay closures. This option allows isolation between the PLC and the Hipot tester.
Safety
Visual Indicator of Voltage Provided by front panel meter, directly connected to high voltage output.
Output
Failure Indicator Audible, provided by buzzer.-isual, Provided by red LED's.-Test automatically terminated on failure.
Leakage Test Provided, 1 mA AC factory set pass/fail point, user adjustable.