Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Compliance HT-2000S 0-2000VAC

Mã sản phẩm:
Sử dụng cho Model:
Hãng SX: Compliance
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Features


Logic controlled, one button test, easy to setup, LED's indicate test progress. Upon failure, buzzer sounds and testing is terminated.
Output voltage, leakage current limit, Ground continuity limit, voltage ramp-up time and test duration are controlled from the rear panel.
Ground continuity test is defeatable for testing of two wire products.
Nema 5-15R receptacle provided on front panel for high voltage output. Not Available on HT-4200S
Operation instructions provided on the rear panel.
Performs UL and CSA safety agency requirements for production Hipot testing.
The HT-S series Hipot tester with adjustable voltage output, voltage ramp, test time, leakage current and ground continuity limit setting.
Can be connected to the GF-30AC-T ground bond tester for complete TUV and European safety testing, with the TESTLINK option.
Support PLC interface for complete automated testing with RI option.
Small footprint and lightweight.
Economical, durable and compact.
Calibration certificate included.
6" Drop test.
1 Year calibration cicle.
1 Year warranty.


HT2000S Specifications
Voltage Range 0-2000 AC
Leakage Current Set Point 1-20 mA AC
Input Voltage Requirements 117-127 V, 50 /60 Hz
Fuse Requirements 120 V, 2 A Slow Blow
Arc Detect Independent High Frequency Circuit
Leakage Detect Independent Low Frequency Circuit
Ground Continuity Set Point 0.08 Ω - 1.50 Ω, Defeatable
Ground Continuity Test Current 100 mA
Test Time Range 1 - 60 Seconds
Ramp Time Range 1 - 5 Seconds
Voltage Meter Accuracy ± 2 %
HV Shutdown by Ground Fail < 7 mS
Duty Cycle 100%
Discharge Time < 7 mS VAC
Transformer Power < 500 VA
Pass/Fail Repeat-ability ± 3 %
Output Connector NEMA plug
Display 4 digits LED display
Test Indicator Led indicators
Failure Indicator Led indicators and buzzer
Programmable No
PLC Interface Optional
TestLink (With GF-30AC) Optional
Computer Control No
Voltage Hold on failure No
Top Mounted Handle Optional
Test Defeat Ground Continuity
Autoreset on Pass Optional
Operation Temperature 15 - 40 °C
Relative Humidity Range 0 - 90 % Non-condensing
Dimensions 9.25" wide x 4.75" high x 10" deep
Weight 11 Lbs
Calibration One year calibration Certificate
Test Cords Return Lead, Power Cord
Test Cords Ground Continuity Connector Tip
Test Cords J2 and J3 Optional
Test Cords Alligator Clip


Bình luận