Feature:
Simulates contact between a power system primary and a telecommunications cable
Simulates long duration induction as a result of a power system fault to earth
Simulates short term induction as a result of a power system primary fault to a multi-earth neutral
Performs GR-1089 1st & 2nd Level AC power fault tests
Performs UL 1950 Annex NAC powerline cross overvoltage tests
Performs ITU-T Power Induction and Earth Potential tests
Performs common mode (longitudinal) and differential mode (metallic) overvoltage tests
Adjustable source impedance
40 and 60 amp per channel models
Single and dual channel models for 2 and 4 wire testing
Preset and variable test times
0-volt or random switching
Operate from computer or front panel
Self contained in standard rack cabinet
Specification |
BLUE AREA |
Output Voltage and Current |
0-600V, 10Ω source impedance, up to 60A; 2 channels, 5s max
0-600V, 15Ω source impedance, up to 40A; 2 channels, 5s max
0-600V, 20Ω source impedance, up to 30A; 2 channels, 5s max
0-600V, 85.7Ω source impedance, up to 7A; 2 channels, 5s max
0-600V, 120Ω source impedance, up to 5A; 2 channels, continuous duty
0-300V, 15Ω source impedance, up to 20A; 2 channels, continuous duty
0-277V, 11.1Ω source impedance, up to 25A; 2 channels, continuous duty
0-277V, 13.8Ω source impedance, up to 20A; 2 channels, continuous duty
0-230V, 10Ω source impedance, up to 23A; 2 channels, continuous duty
0-230V, 20Ω source impedance, up to 11.5A; 2 channels, continuous duty
0-230V, 40Ω source impedance, up to 5.8A; 2 channels, continuous duty
0-230V, 80Ω source impedance, up to 2.9A; 2 channels, continuous duty
0-120V, 8.4Ω source impedance, up to 25A; 2 channels, continuous duty
0-600V, 90-272Ω source impedance continuously variable, up to 2.2A continuous or 3A for ones, 2 channels, continuous duty
0-600V, 272-440Ω source impedance continuously variable, up to 600V, 2 channels, continuous duty
0-600V, 440-2390Ωs source impedance continuously variable, up to 600V, 2 channels, continuous duty
0-600V, 2350-13.6Kohm source impedance, continuously variable, up to 600V, 2 channels, continuous duty
0-600V, 2Ω source impedance, up to 300A; 2 channels, 0.5s max. (must be used in conjunction with Line Simulator Fuse adjacent) |
YELLOW AREA (First Level AC Power Fault) |
Output Voltage and Current |
0-1000V, 1Kohm source impedance, up to 1A; 4 channels, continuous duty
0-1000V, 200Ω source impedance, up to 5A; 4 channels, 0.5s max |
VIOLET AREA |
(High Impedance Inductive Source Test): Output voltage and current |
0-600V, In accordance with GR-1089, Third Edition, Table 4-7 Test 5 and Table 4-8 Test 5
Circuit as shown in GR-1089, Third Edition, Figure 4-4
Supplied with outputs VT and VR
Sensing Points: Sense points V and V'; VT and VR in accordance with GR-1089, Third Edition, Figure 4-4 |
|