Features
The MegaPulses are used with a general purpose oscilloscope for waveform capture and evaluation.
The MEGAPULSE 746E is designed to test Conformal Coatings in accordance with UL 746E, Paragraph 19.3 at up to 6kV.
Output: |
In accordance with UL 746E, Para. 19.3, a-c. |
Voltage Rise Time: |
+/- 30% (400V +) |
Voltage Fall Time: |
+/- 20% (400V +) |
Source Impedance: |
50ohm +/- 10% |
Source Energy: |
not defined |
Mode of Operation: |
Automatic; stop with external interlock. |
Charge Time: |
<60 sec. |