Hotline: 0984.843.683 Email: info@ttech.vn  Zalo: 0984.843.683

Compliance West HT-3000P AC/DC Hipot/Ground Continuity Tester

Mã sản phẩm:
Sử dụng cho Model:
Hãng SX: Compliance
Xuất xứ
Bảo hành
Tình trạng

Tình trạng: Còn hàng

Đặt hàng

Liên Hệ Hỗ Trợ

    • SĐT: 0984 843 683

    • Mail: info@ttech.vn

      • Zalo: 0984.843.683

Thông tin sản phẩm

Features

Adds high precision leakage current and duration settings to the user-friendly HT-3000 for better control of tests.
Allows no load setup of leakage current and test dwell times.
Once entered, leakage current and test dwell times can be referenced on the front panel display at any time.
Leakage currents can be set from 1-5mA in 0.1mA increments.
Dwell times can be set from 1-60 seconds in 1 second increments.
Two tests with one setup. Conducts UL/CSA Ground continuity and Hipot tests with one setup, so no additional equipment is needed.
Small and light. 9.25" wide x 4.25" high x 10" deep. 11 lbs. But rugged enough to test manufactured housing.
Ground continuity check is defeatable for testing two-wire products.
Easy equipment connections. Plug your equipment right into the NEMA plug on the front panel. No adapters needed!
J2 and J3 cords allow connection of pigtail power leads.
Simple test outcome judgement. Green lights mean pass - red lights mean fail. Failing tests sound a buzzer as well.
Ready for your UL Inspector out of the box. NIST Traceable Calibration Certificate to MIL-STD45662-A is included. Cal cert is in accordance with UL guidance.
Operation Instructions are printed on the rear panel for easy reference.
In-depth testing. Both true Arc Dectection and Leakage Current circuits test the product to find problems.
RED lights and a buzzer leave no question if a failure has occurred.
Expandable for TUV/European Agency Testing. Can be connected to our GF-30ac 25A Ground Bond Tester with optional TEST-LINK.
Optional 120kohm calibration resistor can be mounted on the rear panel.
Easy shift-by-shift Function Test. Compatible with our Patented function checker, the HTT-1.


Output 2000Vac 20mA or 2800Vdc 5mA +0 - 10%
Current limit and test time set without HV output
True arc detection via high frequency transformer
Buzzer, lamp upon fail
Optional PLC Interface
Continuity Test
Test status with lights
Failure for Continuity, Leakage Current, Arc Detect
NEMA Plug
Calibration Certificate Included
Shipping weight 14 lbs.
Enclosure size 9" wide x 4-3/4" high x 10" deep
Meter Accuracy ?2% 500v-Full scale (view AC or DC accuracy graph)
Leakage Current Setting 1-20mA AC and 1-5mA DC in 0.1mA increments, using LED meter
Voltage Ramp Time User adjustable 1-5 sec
Test Time 1-60 Sec in 1 sec increments, using LED meter
Duty cycle Continuous
Discharge Time Dependent on output voltage; progress shown on LED meter
Test Adjustments Tamperproof by removing knob
Input Power Requirements 114-127Vac 50/60Hz



Bình luận