Features
Built to the requirements of IEC 1180-1, Voltage Testers.
Generates the waveforms described in EN60335, Paragraph 14 for testing electrical separation.
Theoretical graphs and actual graphs showing the output of your tester are included with each MegaPulse, allowing easy sanity checks and proof to visiting agency engineers of test setups.
Reverse polarity waveforms available by pushing a button on the front panel. No need to change the test setup. Positive polarity indication minimizes errors.
Front panel voltage meter shows residual voltage in charging circuit for safer operation.
Ships with cables, graphs of theoretical and actual waveforms.
Calibration Certificate to ANSI Z540. A2LA Calibration Optional.
One year warranty.
Output Peak: |
400V – 12kV Tolerance ±3% |
Open Circuit Rise Time: |
1.2uS, tolerance ±30% [Trise=1.67(T90%-T30%)] |
Open Circuit Duration Time: |
50uS, tolerance ±20% |
Short peak current: |
1000A for 12ohm output testers
300A for 39ohm output testers |
Voltage Control: |
Manually, by turning a knob in front panel |
Polarity Control: |
Positive and negative. Alternating control available with optional computer control |
Charge Time: |
3 seconds nominal |
Voltage Display: |
5 digit LED display |
Voltage Meter Accuracy: |
400 to 999V ±10V, 1000 to 12000V ±50V |
Duty Cycle: |
A pulse every 60s for the test above 6kV, 30s for 6kV or less |
Line Voltage: |
120V AC, 50/60Hz *optional different line voltage |
Operating Temperature: |
15-40 ºC |
Relative Humidity Range: |
0-90% non-condensing |
Dimensions: |
17” wide x 12” high x 17” in deep |
Weight: |
40 lbs approx |