Earth Continuity
| Test Current |
+/- 200mA DC |
| Display Range |
0.01 – 19.99Ω |
| Pass Value |
User Defined |
Insulation Resistance
| Test Voltage |
500V / 250V DC @ 1mA nominal |
| Display Range |
0.01MΩ - 19.99MΩ |
| Pass Value |
User Defined |
IEC Lead Test
| Test Voltage |
5V ac nominal |
| Test |
Live / Neutral Checks for o/c, s/c and crossed |
Protective Conductor Current/Load
| Test Voltage |
Supply voltage, maximum load current 16A |
| Display Ranges |
0.01mA to 19.99mA |
| Pass Value |
User Defined |
Touch Current
| Test Voltage |
Supply Voltage, maximum load current 16A |
| Display Ranges |
0.00 – 3.50mA |
| Pass Value |
User defined |
Load Power/Current
| Test Voltage |
230V +10%, -15%, maximum load current 16A |
| Test Duration |
Programmable up to a maximum of 255s depending on load. i.e. max duration is reduced for high loads. |
| Display Range |
0.00kVA – 4.00kVA
0.00A – 16.00A |
Alternative Leakage Current
| Test Voltage |
>25Vac <50Vac |
| Display Range |
0.00mA to 19.99mA |
| Pass Value |
User Defined |
RCD Test
| Test Voltage |
230V +10%, -15% |
| Test Current |
30mA / 150mA rms sinusoidal |
| Display Range |
0ms - 2000ms |
| Test method |
Internal isolation to avoid tripping distribution board RCD |
Power Socket Test
| Voltage Range |
207V – 253Vac |
| Indicates configuration of voltage potential:- |
|
| Line potential phase to earth |
|
| Line potential phase to neutral |
|
| Line potential neutral to earth |
|
General
| Memory size |
50,000 records & 2,000 photos |
| Weight |
1.5kg |
| Dimensions |
230mm x 150mm x 100mm |
| Power Source |
Mains or rechargeable battery pack |
Standard Accessories (supplied with Apollo 600)
| Apollo checkbox |
| 2x test leads and probes with crocodile clips |
| 0.5m IEC lead |
| 110V test adaptor |
| Mains power lead |
| USB download cable |
| 30 day free trial of PATGuard 3 Health and Safety Edition |
| Quick start guide |
| Carry case |
|