Flash/Hipot Test (Class I)
Test Voltage Class l |
1.25kV AC |
Display Range |
0.1 - 10 mA AC |
Resolution |
0.01mA |
Accuracy |
+/- 5% +/- 2 digits |
Pass Levels |
selectable up to 10mA |
Flash/Hipot Test (Class II)
Test Voltage Class ll |
2.5 kV AC |
Display Range |
0.1 - 10 mA AC. |
Resolution |
0.01mA |
Accuracy |
+/- 5% +/- 2 digits |
Pass Levels |
selectable up to 10mA |
DC Insulation Test
Test Voltage |
500V |
Display Range |
0.1 - 99.99MΩ |
Accuracy |
+/- 5% +/- 2 digits (up to 19.99MΩ) |
Earth/Ground Bond Test
Test Voltage |
6V AC (open circuit) |
Test Current |
25A, 10A, 4A, 100mA AC into short circuit |
Range |
0.04Ω - 20Ω |
Resolution |
1mΩ |
Accuracy |
+/- 5% +/- 2 digits |
Pass Levels |
user selectable |
Substitute Leakage (Short to Case Test)
Test Voltage |
40V AC o/c |
Display Range |
0.1 - 20.0mA AC |
Resolution |
0.01mA |
Accuracy |
+/- 10% +/- 2 digits (1.00 - 20mA) |
Pass Levels |
selectable up to 15mA |
Earth Leakage
Test Voltage |
Mains Supply |
Display Range |
0.1 - 20.0mA AC |
Resolution |
0.01mA |
Accuracy |
+/- 10% +/- 2 digits (1.00 - 20mA) |
Pass Levels |
selectable up to 10mA |
Power / Run / Load Tests
Resolution |
0.01kVA |
Measured Load |
0 - 4kVA |
Accuracy |
+/- 10 of reading, +/- 2 digits
|
|