Earth Continuity
| Test Currents |
25A, 10A, 4A, AC |
| Display Range |
0.00ohms - 19.99ohms |
| Pass Value |
User Defined |
| Measurement Technique |
4 Wire Measurement, Floating Earth |
Earth Screen Continuity
| Test Current |
100mA |
| Display Range |
0.00ohms - 19.99ohms |
| Pass Value |
User Defined |
| Measurement Technique |
4 Wire Measurement, Floating Earth |
Insulation Resistance
| Test Voltage |
250V, 500V DC |
| Display Range |
0.1Mohms - 100Mohms |
| Pass Value |
User Defined |
Flash
| Test Voltage |
Class I 1500V mns |
| Test Voltage |
Class II 3000V rms |
| Display Range |
0.05mA- 2.5mA |
| Pass Value |
User Defined |
RCD Trip Time Test
| Test Current |
30mA |
| Display Range |
0ms - 500ms |
| Pass Value |
200ms |
Protective Conductor Current
| Test Voltage |
230V/110V |
| Display Range |
0.1mA - 10mA |
| Pass Value |
User Defined |
Touch Current
| Test Voltage |
230V/110V User Selectable |
| Display Range |
0.1mA - 2.0mA |
| Pass Value |
User Defined |
Substitute Leakage
| Test Voltage |
40V AC Nominal |
| Display Range |
0.1mA - 2.0mA |
| Pass Value |
User Defined |
Load Test
| Display Range |
0kVA - 4.2kVA |
|