*Long-term zero stability of <0.2% full scale per year
*Fast flow response to command changes with negligible overshoot/undershoot
*Wide range of flow ratings - from 3 sccm up to 1000 slpm
*High pressure rating - up to 1,500 psi
*Removable flow sensor
*Insensitive to mounting attitude
*Mechanically and electrically compatible with other mass flow controllers
*Electrically activated valve override
*Corrosion-resistant valve
Thông số kỹ thuật
Differentiator
|
*Proven Reliable Performance
*Long Term Stability
*Easy to Change Range and Recalibrate in the Field
|
Performance
|
Flow Range (Full Scale Capacity)
|
*0 - 1000 slpm
|
Accuracy
|
*1% of FS
*1.5% of FS > 20 slpm
|
Repeatability
|
*0.25% of Rate
|
Linearity
|
*Included in accuracy
|
Response Time
|
*E Series Controllers: < 3 seconds
*I Series Controllers: < 6 seconds
*Meters: 6 Seconds
|
Multi-Gas & Range Configurability
|
-
|
Max Pressure
|
*Controllers: 1500 psig
*Meters: up to 4500 psig on some models
|
Control Range
|
*50:1
|
Zero Stability
|
*< 0.2% F.S. per year
|
Flow Temperature Coefficient
|
*Zero: <0.075% of F.S per oC
*Span: <1.0% of S.P. over 10-50 oC
|
Input / Output
|
*0-5 Vdc
*I Series: 0-20 mA; 4-20 mA
|
Ratings
|
Ratings
|
Max Temperature
|
*65oC
|
Mechanical
|
Seal Material
|
*Elastomer Seal
|
Diagnostics
|
Diagnostic Capability
|
-
|
Electrical
|
Analog Communication
|
*0-5 Vdc
*0-20 mA
*4-20 mA
|
|
*Electrical Connection
|
*D-type connector
|
Power Supply / Consumption
|
*< 10.5 watts
|