Measurement: |
4 Terminal Kelvin / Thomson principle eliminates errors due to lead resistance. |
Display: |
LCD graphics panel with backlit 30,000 count |
Ranges: |
8 automatic or manual selection |
Terminals: |
4mm safety sockets |
Working temperature: |
0°C to +45°C rel. humidity 80% max. non-condensing |
Storage Temperature: |
-20°C to +60°C |
Mains Supply: |
115/230 Volts +10%-10%
47 to 63Hz 20VA |
Safety: |
EN 61010-1 EMC - EN 61236 |
Dimensions: |
339mm x 324mm x 131mm (W H D) approx |
Mass: |
12kg approx. 12kg packed in carton |
Auto Zero: |
Permits the zero of measurement values |
Average: |
Automatic average and display of measurement with forward and reverse current |
Auto Temperature Compensation: |
Automatically references measurement to temperature of 20°C or user defined temperature. User coefficients may be used. External Pt100 senses temperature manual value can be used |
Hi / Lo Limits: |
Limit values can be set over entire measurement range |
Calibration: |
Digital pass code protected |
Protection: |
415 Vrms maximum at the measuring terminals will blow internal protection fuse |
Range |
Resolution |
Typical Current |
Maximum Current |
Accuracy at Full Rated Current |
30k Ω |
1 Ω |
10µA |
100µA |
±(0.03% Rdg +0.02% FS) |
3k Ω |
100m Ω |
100µA |
1m A |
±(0.03% Rdg +0.01% FS) |
300 Ω |
10m Ω |
1mA |
10m A |
±(0.03% Rdg +0.01% FS) |
30 Ω |
1m Ω |
10mA |
100m A |
±(0.03% Rdg +0.01% FS) |
3 Ω |
100µ Ω |
10mA |
100m A |
±(0.03% Rdg +0.01% FS) |
200m Ω |
10µ Ω |
10mA |
100m A |
±(0.03% Rdg +0.01% FS) |